依据电磁兼容指令[EMC]以及相关标准,我们为电气产品提供可靠的、高质量的实验室检测服务。我们的实验室始终专注于各类产品的电磁兼容技术相关的检测服务。
适用的产品类别:
- 无线电及附属设备
- 工业、科研及医药设备[ISM]
- 信息技术设备
- 电气照明及类似设备
- 航海相关的无线电通信设备及系统
- 电子电气产品
- 家用、商用及轻工业环境下的电子电气设备
- 工业环境下的电子电气设备
- 低电压设施相关的电力通信设备
- 信息处理设备(ITE),无线通信终端设备
- 轨道应用 – 信号传输和通信设备
- 可调速的电气驱动装置
- 电梯、扶梯及人行道相关的电气系统
- 报警系统
- 家用或类似用途的自动控制装置
- 车辆使用的电子电气产品
- 家用电器
- 医用电气设备
- 电动伸缩门
- 散热器
- 两轮或三轮机动车辆
- 车辆及其电子电气单元
适用的实验室检测标准:
Radio and Ancillary Equipment: EN 300 220-2:2010, EN 300 220-2:2012, EN 300 328:2006, EN 300 328:2012, EN 300 330-2:2010, EN 300 440-2:2010, EN 301 511:2003, EN 301 893:2008, EN 301 893:2012. |
Industrial Scientific and Medical [ISM] Equipment Radio Frequency:EN 55016-1-2 (2004) + A1 (2005) = CISPR 16-1-2 (2003) + A1 (2004); EN 55011 (2007) + A2 (2007) = CISPR 11 (2003) +A1(2004) +A2 (2006); CISPR 11 (2003); EN 55011 (2009) + A1 (2010) = CISPR 11 (2009) + A1(2010) |
Information technology equipment: EN 60950-1:2006 EN 60950-1/A11:2009 EN 60950-1/A1:2010 EN 60950-1/AC:2011 EN 60950-1/A12:2012 IEC 60950-1:2005 IEC 60950-1/am1:2009 IEC 60950-1:2012 |
Electrical lighting and similar equipment: - Conducted disturbance emission test (0,009 - 30 MHz): EN 55016-1-2 (2004) + A1 (2005) = CISPR 16-1-2 (2003) + A1 (2004); EN 55015 (2006) + A1 (2007) + A2 (2009) = CISPR 15 (2005) + A1 (2006) + A2 (2008); EN 55015: 2013 - Radiated disturbance emission test (30 - 300 MHz): EN 55016-1-4 (2012) = CISPR 16-1-4 (2010); EN 55015 (2006) + A1 (2007) + A2 (2009) = CISPR 15 (2005) + A1 (2006) + A2 (2008); EN 55015: 2013 - EMC immunity requirements (Tabella 2, EN 61547:2009): EN 61547: 2009-08 |
Maritime navigation and radio-communication equipment and systems: EN 60945:2002 |
Electrical and electronic equipment: - Harmonic current emissions (I<16A) (0-2 kHz): EN 61000-3-2 (2006) +A1 (2008) +A2 (2009) = IEC 61000-3-2 (2005) +A1(2008)+ A2(2009) - Harmonic current emissions (I<20A) (0-2 kHz): EN 61000-3-12: 2011 - Voltage fluctuations and flicker (I < 16A): EN 61000-3-3:1995 EN 61000-3-3/A1:2001 EN61000-3-3/A2:2005 EN 61000-3-3/IS1:2005; EN 61000-3-3: 2008; EN 61000-3-3:2013 - Voltage fluctuations and flicker (I < 20A): EN 61000-3-11: 2000 - Immunity to Mains Frequency Magnetic Fields (100 A/m CW; 300 A/m pulse): EN 61000-4-8 (1993) + A1 (2001) = IEC 61000-4-8 (1993) + A1 (2000) - Immunity to conducted disturbances, induced by radio-frequency fields (0,15-230 MHz): EN 61000-4-6 (2003) = IEC 61000-4-6 (2003) + A1 (2004) + A2 (2006); EN 61000-4-6 (2008) = IEC 61000-4-6 (2009) - Electrical fast transient: EN 61000-4-4 (2004) + A1 (2010) = IEC 61000-4-4 (2004) + A1 (2010) - Radiated, radio-frequency, electromagnetic field immunity test (80-6000 MHz): EN 61000-4-3 (2006) + A1 (2008) + A2 (2010) = IEC 61000-4-3 (2006) + A1 (2007) + A2 (2010) - Surge immunity test:EN 61000-4-5 (2006) = IEC 61000-4-5 (2005) - Electrostatic discharge immunity test (fino a +/- 8 kV a contatto e +/- 15 kV in aria): EN 61000-4-2 (1995) + A1(1998) + A2(2001) = EN 61000-4-2 (1995) + A1 (1998) + A2(2000); EN 61000-4-2 (2009) = IEC 61000-4-2 (2008) - Voltage dips, short interruptions and voltage variations immunity tests: EN 61000-4-11 (2004) = IEC 61000-4-11 (2004) |
Electrical and electronic equipment residential, commercial and light-industrial environments: - Electromagnetic compatibility - generic standard – emission: EN 61000-6-3:2007; EN 61000-6-3/A1:2011 - Electromagnetic compatibility - generic standard – immunity: EN 61000-6-1:2007 |
Electrical and electronic equipment for industrial environments: - Electromagnetic compatibility - generic standard – emission: EN 61000-6-4:2007; EN 61000-6-4/A1:2011 - Electromagnetic compatibility - generic standard – immunity: EN 61000-6-2:2005 |
Equipment for power lines communication "PLC" used in low-voltage installations - Radio disturbance characteristics - Limits and methods of measurement - Part 1: Household equipment: EN 50561-1:2013 |
Information Treatment Equipment (ITE), Radio and Telecommunication Terminal Equipment - Immunity characteristics: EN 55024:1998 EN 55024/A1:2001 EN55024/A2:2003 EN 55024/IS1:2007; EN 55024:2010 - Radiated electromagnetic interference emission (150 k - 18000 MHz): EN 55016-1-4 (2012) = CISPR 16-1-4 (2010); EN 55022 (1998) + A1 (2000) + A2 (2003) = CISPR 22 (1997) + A1 (2000) + A2 (2002); EN 55022 (2006) + A1 (2007) = CISPR 22 (2005) + A1(2005) ;CISPR 22 (2008);ETSI EN 301489-1 V1.9.2; (2011-09);ETSI EN 301489-3 v.1.6.1 (2013-08); ETSI EN 301489-7 v1.3.1 (2005-11); ETSI EN 301489-17 v.2.2.1 (2012-09);EN ETSI 301489-24 v.1.5.1 (2010-12) - Continuous radio interference voltage emission (9 k - 30 MHz): EN 55016-1-2 (2004) + A1 (2005) = CISPR 16-1-2 (2003) + A1 (2004); CISPR 16-1-2 (2014) EN 55022 (1998) + A1 (2000) + A2 (2003) = CISPR 22 (1997) + A1 (2000) + A2 (2002); EN 55022 (2006) + A1 (2007) = CISPR 22 (2005) + A1(2005) ;CISPR 22 (2008); ETSI EN 301489-1 V1.9.2; (2011-09);ETSI EN 301489-3 v.1.6.1 (2013-08); ETSI EN 301489-7 v1.3.1 (2005-11); ETSI EN 301489-17 v.2.2.1 (2012-09);EN ETSI 301489-24 v.1.5.1 (2010-12)) |
Railway applications - Electromagnetic compatibility - Part 4 : emission and immunity of the signalling and telecommunications apparatus: EN 50121-4:2006 |
Railway applications - Electromagnetic compatibility - Part 3-2 : rolling stock – Apparatus: EN 50121-3-2: 2006 |
Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods: EN 61800-3:2004; EN 61800-3/A1:2012 |
Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks. Immunity: EN 12016:2013 |
Electromagnetic compatibility. Product family standard for lifts, escalators and moving walks. Emission: EN 12015:2004 |
Alarm systems - Electromagnetic compatibility and Environmental test methods: EN 50130-4:1995 EN 50130-4/A1:1998 EN50130-4/A2:2003 |
Automatic electrical controls for household and similar use - electromagnetic compatibility:EN 60730-1:2000 + A1:2004 + A12:2003 + A13:2004 + A14:2005 + A18:2003 + A15:2007 + A16:2007 + A2:2008 |
Electrical and electronic applications for vehicular: - Electrical disturbances from conduction and coupling -- Part 1: Definitions and general considerations: ISO 7637-1:2002 ISO7637-1/Amd1:2008 - Electrical disturbances from conduction and coupling -- Part 2: Electrical transient conduction along supply lines only: ISO 7637-2:2004 ISO 7637-2:2011 - Limits and methods of measurement of radio disturbance characteristics for the protection of receivers used on board vehicles and devices: CISPR 25 (2008) Radiated emission from component/module - Test Procedure and limits Paragraph 6,4 Test method: ALSE - Limits and methods of measurement of radio disturbance characteristics for the protection of receivers used on board vehicles and devices: CISPR 25 (2008) Conducted emission from component/module - Paragraph 6,2 Test method: Voltage measurements. - Immunity test - Absorber-lined shielded enclosure method Max applicable field = 200 V/m up to frequency 1 GHz; max applicable field = 30 V/m above 1 GHz to 2 GHz: ISO 11452-1:2005 + Amd1:2008 + ISO 11452-2:2004, Dir. 2004/104/CE 14/10/2004 GU UE L337 13/11/2004 (All. IX), Dir. 2009/19/CE 12/03/2009 GU UE L70 14/03/2009, Reg. UNECE R10 14/08/2008 (All. 9) + Cor. 1: 2010 + Amd1:2011, Reg. UNECE R10 06/03/2012 (All. 9) + Cor. 1: 2012 + Amd1:2012 - Immunity test - Bulk Current Injection (BCI) method Max applicable current = 200 mA Operating frequency range: f min = 1 MHz; f max = 400 MHz): ISO 11452-1:2005 + Amd1:2008 + ISO 11452-4:2005 + Cor 1:2009, ISO 11452-4:2011 - Road vehicles -- Electrical disturbances from conduction and coupling – Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines: ISO 7637-3:2007 |
Household appliances: - Clic (0,15-30 MHz): EN 55014-1 (2006) + A1 (2009) + A2 (2011) = CISPR 14-1 (2005) + A1 (2008) + A2 (2011) - Radiated electromagnetic interference emission (30-1000 MHz): EN 55014-1 (2006) + A1 (2009) + A2 (2011) = CISPR 14-1 (2005) + A1 (2008) + A2 (2011); - Disturbance power (30–300 MHz): EN 55016-1-3 (2006) = CISPR 16-1-3 (2004) EN 55014-1 (2006) + A1 (2009) + A2 (2011) = CISPR 14-1 (2005) + A1 (2008) + A2 (2011); - Continuous radio interference voltage emission(9 k - 30 MHz): EN 55014-1 (2006) + A1 (2009) + A2 (2011) = CISPR 14-1 (2005) + A1 (2008) + A2 (2011); - Immunity test: EN 55014-2:1997+ A1:2001 + A2: 2008 = CISPR 14-2:1997 + A1:2001 +A2: 2008 |
Industrial, Scientific, and Medical Equipment (ISM): FCC CFR 47 Part 18 FCC MP-5 (1986) |
Medical electrical equipment - Part 2-5: Particular requirements for the safety of ultrasonic physiotherapy equipment: IEC 60601-2-5:2009, EN 60601-2-5:2000 |
Power operated pedestrian doors. Product standard, performance characteristics. Pedestrian doorsets, other than swing type, initially designed for installation with power operation without resistance to fire and smoke leakage characteristics - EMC requirements: EN 16361:2013 |
Radio Frequency Devices/Intentional Radiators - FCC Methods of Measurements of Radio Noise Emissions From Industrial, Scientific, and Medical Equipment: FCC CFR 47 Part 15 Subpart C ANSI C63.4-2003 ANSI C63.4-2009, |
Radio Frequency Devices/Unintentional Radiators - FCC Methods of Measurements of Radio Noise Emissions From Industrial, Scientific, and Medical Equipment: FCC CFR 47 Part 15 Subpart B ANSI C63.4-2003 ANSI C63.4-2009, |
Two or three-wheel motor vehicles - Electromagnetic compatibility of two or three-wheel motor vehicles and electrical or electronic separate technical units: Direttiva 97/24/EC fino all'ultimo emendamento Direttiva 2009/108/EC limitatamente agli allegati II, III, IV, V, VI e VII / Directive 97/24/EC until the last amendment to Directive 2009/108/EC limited to Annexes II, III, IV, V, VI and VII |
Vehicles and electrical-electronic unit - Method of measurement of radiated broadband and narrowband electromagnetic emissions from electrical-electronic subassemblies. Method of testing for immunity of electrical/electronic subassemblies to electromagnetic radiation. Method(s) of testing for immunity to and emission of transients of electrical/electronic subassemblies: Direttiva 2004/104/CE fino all'ultimo emendamento Direttiva 2009/19/EC ECE R10-04 (limitatamente agli allegati VII, VIII, IX e X relativi alle prove di emission ed immunità delle unità elettriche/elettroniche per applicazioni veicolistiche) / Directive 2004/104/EC until the last amendment to Directive 2009/19/EC ECE R10-04 (limited to Annexes VII, VIII, IX and X concerning emission and immunity tests of electrical / electronic applications for vehicles) |