 The High Voltage and Dielectric Tests Labs, perform Dielectric Tests in High Voltage, Medium Voltage and Low Voltage Electrical Materials


Main Tests

  • Lightning Impulse Voltage tests 1,2 /50μS full wave and chopped on the tail up to 1,800kV.
  • Power frequency voltage tests up to 300kV under dry or wet conditions.
  • Dielectric tests at variable humidity and temperature, under water immersion and under pollution.
  • Direct current tests up to 200kV and induced voltage tests (200Hz) up to 1kV.
  • Partial discharges, radio interference voltage, power loss, tanδ, capacitance measurements.
  • Investigation  tests.


Main Equipment

  • Impulse voltage Generator 1800 KV, 90KJ, waveform  1,2/50μS
  • Digital recorder of impulse voltages & currents,
  • AC Dielectric test  transformer 0 -300kV/ 1A , 50Hz
  • AC Generator 50 Hz,  0-100KV /100mA, 50Hz  WP10/100
  • DC Generator 0-200kV/200mA ,
  • 3- phase Generator 200 Hz,  380 V 
  • PD measuring system


 适用的实验室检测标准:

TEST WITH LIGHTNING IMPULSE CHOPPED ON THE TAIL (LIC) FOR POWER TRANSFORMERS  (IEC 60076-3) 
SEPARATE SOURCE AC WITHSTAND VOLTAGE TEST FOR POWER TRANSFORMERS   (IEC 60076-3) 
INDUCED AC VOLTAGE TESTS FOR POWER TRANSFORMERS  (IEC 60076-3) 
MEASURMENT OF RADIO INTERFERENCE VOLTAGE (RIV) FOR POWER TRANSFORMERS   (IEC 60437) 
IMPULSE TEST ON PRIMARY WINDING OF HV VOLTAGE TRANSFORMERS (1 PC)   (IEC 60044-2) 
WET TEST FOR OUTDOOR TYPE HV VOLTAGE TRANSFORMERS (1 PC)  (IEC 60044-2) 
POWER-FREQUENCY WITHSTAND TESTS ON PRIMARY WINDINGS OF HV VOLTAGE TRANSFORMERS (1 PC)   (IEC 60044-2) 
INDUCED AC VOLTAGE TESTS ON HV VOLTAGE TRANSFORMERS.   (IEC 60044-2) 
PARTIAL DISCHARGE MEASUREMENT ON HV VOLTAGE TRANSFORMERS (1 PC)   (IEC 60044-2) 
POWER-FREQUENCY WITHSTAND TESTS ON SECONDARY WINDINGS AND BETWEEN SECTIONS ON HV VOLTAGE TRANSFORMERS. (1 PC)   (IEC 60044-2) 
IMPULSE TEST ON PRIMARY WINDING OF HV CURRENT TRANSFORMERS (1 PC)  (IEC 60044-2) 
WET TEST FOR OUTDOOR TYPE LV OR HV CURRENT TRANSFORMERS (1 PC)  (IEC 60044-2) 
POWER-FREQUENCY WITHSTAND TESTS ON PRIMARY WINDINGS OF HV CURRENT TRANSFORMERS (1 PC)  (IEC 60044-2) 
PARTIAL DISCHARGE MEASUREMENT ON HV CURRENT TRANSFORMERS (1PC)   (IEC 60044-2) 
POWER-FREQUENCY WITHSTAND TESTS ON SECONDARY WINDINGS AND BETWEEN SECTIONS ON LV OR HV CURRENT TRANSFORMERS (1PC)   (IEC 60044-2) 
INTER-TURN OVERVOLTAGE TEST ON LV OR HV CURRENT TRANSFORMERS (1PC)   (IEC 60044-2) 
IMPULSE VOLTAGE TEST “TO EARTH AND BETWEEN PHASES” FOR MV METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR   (IEC 62271-102) 
IMPULSE VOLTAGE TEST “TO EARTH AND BETWEEN PHASES ON OPENED SWITCHING DEVICES” FOR MV METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR  (IEC 62271-102 IEC 62271-1) 
IMPULSE VOLTAGE TEST “ ACROSS THE ISOLATING DISTANCE” ON ONE SWITCHING DEVICE” FOR MV METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR   (IEC 62271-102 IEC 62271-1) 
POWER-FREQUENCY WITHSTAND TESTS “TO EARTH AND BETWEEN PHASES” FOR METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR   (IEC 62271-102) 
POWER-FREQUENCY WITHSTAND TESTS “TO EARTH AND BETWEEN PHASES ON OPENED SWITCHING DEVICES” FOR MV METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR   (IEC 62271-102 IEC 62271-1) 
POWER-FREQUENCY WITHSTAND TESTS “ ACROSS THE ISOLATING DISTANCE” ON ONE SWITCHING DEVICE FOR MV METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR   (IEC 62271-102 IEC 62271-1) 
LIGHTNING IMPULSE VOLTAGE TEST ON 1-POLE DISCONNECTORS –FUSE DISCONNECTORS.
POWER-FREQUENCY WITHSTAND TEST ON 1-POLE DISCONNECTORS –FUSE DISCONNECTORS
WET TEST FOR OUTDOOR TYPE 1-POLE DISCONNECTORS –FUSE DISCONNECTORS 
MEASURMENT OF RADIO INTERFERENCE VOLTAGE (RIV) ON 1-POLE DISCONNECTORS –FUSE DISCONNECTORS   (ANSI C37.41) 
LIGHTNING IMPULSE VOLTAGE TEST ON 3-POLE DISCONNECTORS –FUSE DISCONNECTORS   (ΔΔ-310, ΔΔ-312, IEC 62271-102) 
POWER-FREQUENCY WITHSTAND TEST ON 3-POLE DISCONNECTORS –FUSE DISCONNECTORS   (ΔΔ-310, ΔΔ-312, IEC 62271-102) 
WET TEST FOR OUTDOOR TYPE 3-POLE DISCONNECTORS –FUSE DISCONNECTORS   (ΔΔ-310, ΔΔ-312, IEC 62271-102, IEC 600060-1) 
MEASURMENT OF RADIO INTERFERENCE VOLTAGE (RIV) ON 3-POLE DISCONNECTORS –FUSE DISCONNECTORS  (ANSI C37.41, IEC 60437) 
LIGHTNING IMPULSE VOLTAGE TEST ON SWITCH DISCONNECTOR(1-52KV) OUTDOOR TYPE   (IEC 62271-102, IEC 60694) 
POWER-FREQUENCY WITHSTAND TEST ON SWITCH DISCONNECTOR(1-52KV) OUTDOOR TYPE   (IEC 62271-102, IEC 60694) 
WET TEST ON SWITCH DISCONNECTOR(1-52KV) OUTDOOR TYPE   (IEC 62271, IEC 60694) 
MEASURMENT OF RADIO INTERFERENCE VOLTAGE (RIV) ON SWITCH DISCONNECTOR(1-52KV) OUTDOOR TYPE   (IEC 62271) 
CRITICAL IMPULSE VOLTAGE TEST ON HV INSULATORS.   (ANSI C29.1) 
WITHSTAND LIGHTNING IMPULSE VOLTAGE TEST ON HV INSULATORS   (ANSI C29.1) 
WET CRITICAL FLASHOVER VOLTAGE TEST ON HV INSULATORS.   (ANSI C29.1) 
DRY CRITICAL FLASHOVER VOLTAGE TEST ON HV INSULATORS.   (ANSI C29.1) 
PUNCTURE TEST (PORCELAIN OR GLASS) ON HV INSULATORS   (ANSI C29.1) 
MEASURMENT OF RADIO INTERFERENCE VOLTAGE (RIV) ON HV INSULATORS.  (ANSI C29.1) 
LIGHTNING IMPULSE VOLTAGE TEST ON HV ARRESTER.   (IEC 60060-1, IEC 6099-4) 
DRY POWER-FREQUENCY WITHSTAND TEST ON HV ARRESTER.   (IEC 60060-1, IEC 6099-4) 
WET POWER-FREQUENCY WITHSTAND TEST ON HV ARRESTER   (IEC 60060-1, IEC 6099-4) 
PARTIAL DISCHARGE MEASUREMENT ON HV ARRESTER   (IEC 60270, IEC 6099-4) 
BENDING TEST, FOLLOWED BY A PARTIAL DISCHARGE TEST ON SINGLE-CORE HV CABLES (95-630MM2)   (IEC 60502-2) 
TAN Δ MEASUREMENT  (IEC 60502-2) 
PARTIAL DISCHARGE TEST ON SINGLE-CORE HV CABLES (95-630MM2)  (IEC 60502-2, IEC 60885-3) 
HEATING CYCLE TEST, FOLLOWED BY A PARTIAL DISCHARGE TEST ON SINGLE-CORE HV CABLES (95-630MM2)   (IEC 60502-2) 
IMPULSE TEST AT ELEVATED TEMPERATURE, FOLLOWED BY A VOLTAGE TEST AT AMBIENT TEMPERATURE ON SINGLE-CORE HV CABLES (95-630MM2)   (IEC 60502-2, IEC 60230) 
VOLTAGE TEST FOR 4 H ON SINGLE-CORE HV CABLES (95-630MM2)  (IEC 60502-2) 
(63 HEATING CYCLES) TEST ON ACCESSORIES FOR USE ON HV CABLES (95-630MM2)   (HD 629.1 S2, IEC 61442) 
FULL WAVE LIGHTNING IMPULSE TEST (LI) - FOR THE LINE TERMINALS ON POWER TRANSFORMERS 
NUMBER OF LI = 12 
INDUCED VOLTAGE TESTS WITH PARTIAL DISCHARGE MEASUREMENT (IVPD) ON POWER TRANSFORMERS (1 PC)
WATER DIFFUSION TEST ON COMPOSITE INSULATORS (IEC 62217)
CHOPPED IMPULSE TEST ON PRIMARY WINDING ON MEASUREMENT TRANSFORMERS